Data Centers & Computing Halls

Cabinets, containment and power for high-density compute.

Quick answer

Data center projects typically use 42U cabinets, 25 kW to 50 kW row cooling, 10 kVA to 30 kVA UPS and aisle containment. A project can range from 20 to 200 cabinets, with a PUE of about 1.3 to 1.5 and 20 to 45 day delivery.

Last reviewed: 2026-11-07

A data center hall is a system: cabinet depth, airflow, power density and cable routing must be designed together. RackSource supplies the physical layer — server cabinets, cold or hot aisle containment, PDUs and UPS distribution — from one manufacturing base.

For phased projects, the same cabinet family can be delivered in batches while containment and power modules are added row by row. This keeps the hall operational during expansion.

What this environment demands

  • —High power density per rack and uneven heat loads
  • —Mixing cold supply air with hot exhaust
  • —Long cable runs and dense fiber management
  • —Expansion without interrupting live operations

How RackSource approaches it

  • —1200 mm deep server cabinets with mesh doors and blanking panels
  • —Cold or hot aisle containment with fire-release skylights
  • —Metered PDUs and modular UPS with N+1 redundancy
  • —Batch delivery and row-by-row commissioning support
Industry data

Typical deployment data for this application

Compute-hall planning usually starts with rack density, redundancy and cooling architecture. Standard enterprise racks sit around 5–8 kW; virtualization and storage raise this to 10–20 kW; GPU and AI clusters can reach 25–50 kW or more per rack. Containment, row-based cooling and dual-feed power are selected together, not as separate add-ons.

Metric Typical industry range Design note
IT load per rack 5–8 kW standard; 10–20 kW high density; 25–50+ kW AI/GPU Confirm nameplate load and growth margin before selecting PDU and cooling capacity.
Cooling architecture Room CRAC, row-based, in-row or rear-door Match cooling to rack density and aisle layout; verify airflow paths with the containment design.
Power redundancy N+1 or 2N; dual feed to each rack Dual-corded equipment should use two independent PDUs on separate feeds.
Rack dimensions 42–47U, 600/800 mm wide, 1000–1200 mm deep Depth must cover rails, rear cabling and vertical PDU clearance.
Containment Cold aisle or hot aisle; fire-release roof Verify fire strategy, aisle pressure and door clearance with the room design.
Monitoring SNMP, Modbus or DCIM; per-rack metering PDU-level metering simplifies capacity planning and load balancing.

Typical design checklist

  • —Prepare a rack elevation with U positions, equipment depths and power loads.
  • —Confirm power density, redundancy level and UPS runtime.
  • —Check floor loading, seismic zone and cooling layout.
  • —Define cable entry, containment and fire-release interfaces.
  • —Agree acceptance tests and documentation before shipment.

Application questions

Can you match an existing cabinet row?

Yes. Provide the existing cabinet height, depth, frame interface and color reference. We will confirm whether new cabinets can be bayed directly or need a transition module.

How do you support a phased build?

We fix the frame and interface standards at the first batch, then deliver additional cabinets, containment sections and power modules against the same drawings. This avoids reworking the first row.

What documents are supplied?

Cabinet drawings, material and finish certificates, test reports and packing lists. Project-specific O&M manuals can be prepared when required.