Cold Aisle Containment System

Modular skylights, doors and seals that separate cold supply from hot return.

Quick answer

Cold aisle containment seals a 1,200 mm aisle with an aluminum frame, glass or polycarbonate skylight and sliding or swing doors. Typical height is 2,000 mm to 2,200 mm, door size is 900 × 2,000 mm, and the system supports row cooling of 25 kW to 50 kW while cutting mixing losses by 10% to 20%.

Last reviewed: 2026-11-07

JZ-CA cold aisle containment with glass skylights
Cold Aisle Containment System — Image 1
Cold Aisle Containment System — Image 2
Cold Aisle Containment System — Image 3
Key features

The JZ-CA Series encloses the cold aisle between two cabinet rows. Cold air stays in the aisle and reaches the server intakes; hot exhaust returns to the cooling units without mixing.

The frame is independent of the cabinets, so it can be installed before or after the racks. Skylights use aluminum profiles and tempered glass or PC panels; end doors are glass and can be fitted with access control.

  • Independent aluminum frame
  • Modular skylights with fire release
  • Glass end doors with optional access control
  • Blanking panels and cable-entry seals
  • Row-level air-conditioner integration
  • Cross-aisle cable ladder

Technical specifications

Aisle type Cold aisle (hot aisle available)
Frame Aluminum profile, independent support
Skylight Tempered glass or PC panel
Doors Sliding or swing glass door
Fire release Automatic on alarm
Cooling Row-level 25–50 kW units

Typical applications

  • 01 Data centers and computing-power halls
  • 02 Existing rooms with hot-spot problems
  • 03 High-density server rows
  • 04 Micro-module and container projects

What cold aisle containment does

Cold aisle containment separates the cold supply air from the hot return air in a data center row. It encloses the cold aisle with a frame, roof panels and end doors, so the air delivered by the CRAC or in-row units reaches the server intakes instead of mixing with hot exhaust.

The result is a more uniform intake temperature, fewer hot spots and less energy used by the cooling system. Containment is often the lowest-cost way to raise cooling capacity in an existing room before adding more air conditioners.

Dimensions, frame and panels

The aisle width is typically 1,200 mm, which allows two people to pass and gives enough space for door swing and equipment installation. The frame height is usually 2,000 mm to 2,200 mm, matching the cabinet row and the ceiling grid. The frame uses aluminum profiles with adjustable feet and independent support, so it does not load the cabinets.

The roof panels are tempered glass or polycarbonate. Glass gives better light transmission and scratch resistance; polycarbonate is lighter and less likely to shatter. Both should provide 70% to 80% light transmission and a sealed joint between panels.

Doors, sealing and airflow

End doors are sliding or swing glass doors, typically 900 mm wide and 2,000 mm high, with a frame and seals. Sliding doors save space in tight rooms; swing doors give a wider opening for equipment. Magnetic or brush seals close the gaps between doors, panels and cabinets.

The goal is to keep leakage below about 5% of the supply airflow. Seal cable openings, blank unused U positions, and close gaps at the top and bottom of the row. A pressure difference of 5 Pa to 15 Pa between the cold aisle and the room is a useful commissioning check.

Cooling capacity and temperature control

Cold aisle containment is commonly used with row cooling units of 25 kW to 50 kW, or with perimeter CRAC units. The containment does not add cooling capacity; it makes the existing capacity more effective. Confirm the IT load, the supply air temperature and the redundancy before selecting the cooling units.

With good sealing, the intake temperature variation along the row can be kept within 1 °C to 2 °C. That allows a higher supply air temperature and a higher chilled water temperature, which improves chiller efficiency and reduces PUE.

Installation, options and delivery

Installation is modular: mount the vertical posts, add the roof beams, fit the panels, then hang the doors. The frame is adjustable for cabinet width and row length. A typical row of 10 cabinets can be installed in 2 to 4 days after the cabinets are in place.

Options include hot aisle containment, skylight panels with drop-away function, fire-suppression interfaces, blanking panels, brush seals and LED lighting. Typical lead time is 20 to 30 working days after drawing approval, with 1 row as the minimum order.

Cold aisle containment reference specifications

ItemTypical valueNotes
Aisle width1,200 mmTwo-person access
Frame height2,000–2,200 mmMatch cabinet row
Door size900 × 2,000 mmSliding or swing
FrameAluminum profileIndependent support
Roof panelTempered glass / PC70–80% light transmission
Door glassTempered glassSealed frame
Leakage target<5% of supply airCommissioning check
Intake variation1–2 °C along rowWith good sealing
Cooling25–50 kW row unitsBy IT load
Pressure difference5–15 PaCold aisle vs room
FinishAnodized aluminumOptional color
PackagingCarton + cratePanel protection

Configuration options

OptionChoicesTypical use
Aisle typeCold / hotBy room design
DoorSliding / swingSpace and access
RoofGlass / PC / solidLight and fire
SkylightFixed / drop-awayFire suppression
SealsBrush / magneticCable openings
LightingLED stripService access
Blanking1U–4U panelsUnused U positions
ControlDoor sensor / alarmMonitoring

Packing and delivery reference

ItemTypical valueNotes
PackingCarton + wooden crateGlass protection
Added dimensions50–100 mm per sideBy panel
Added weight10–20 kg per meterFrame and panels
Container quantityAbout 20–40 rows per 40HQBy row length
Lead time20–30 working daysAfter drawing approval
Installation2–4 days per rowAfter cabinets

Questions buyers ask

Can containment be retrofitted to an existing row?

Yes, if the cabinets share a consistent height and depth and the row ends can accept doors. A site survey is needed to confirm anchor points, ceiling clearance and fire-system interface.

Does containment replace air conditioning?

No. Containment improves the efficiency of the existing cooling system by stopping mixing. If the cooling capacity is already insufficient, additional row-level or room-level capacity is still required.

What is the typical lead time?

Standard aluminum profiles and glass panels are usually available in 3–5 weeks after drawing approval. Projects with access control, custom colors or fire-release testing need additional time.

What is the difference between cold aisle and hot aisle containment?

Cold aisle containment encloses the cold supply aisle and leaves the hot aisle open to the room. Hot aisle containment encloses the hot return aisle and leaves the cold aisle open. Cold aisle is more common in retrofit projects; hot aisle can be better for high-density rows.

How much energy does cold aisle containment save?

Typical savings are 10% to 20% of cooling energy, depending on the room, the sealing quality and the supply air temperature. The biggest gains come from reducing air mixing and allowing a higher chilled water temperature.

What aisle width should I use?

A 1,200 mm aisle is the common choice for data centers. It allows two people to pass and gives enough room for door swing and equipment installation. Narrower aisles save space but complicate service access.

Does containment work with raised floors?

Yes. The frame can be mounted on the raised floor with adjustable feet, and the floor tiles can be cut for cable and airflow openings. Seal the tile cuts and the frame base to prevent bypass air.

Can containment be added to an existing row?

Yes. The modular frame is designed for retrofit. Measure the cabinet row, the ceiling height and the door access, then order the frame, panels and doors as a kit. Installation can be done without moving the cabinets.

What is the lead time for cold aisle containment?

Typical lead time is 20 to 30 working days after drawing approval, depending on the row length and the panel type.
Start a project