Container Data Center — Prefabricated IT Capacity in a Container

Containerized data centers with racks, power, cooling and monitoring in a transportable shell.

Quick answer

A container data center is an ISO 20 ft or 40 ft module with 10 to 20 racks, integrated UPS, cooling and fire suppression. A 40 ft module typically supports 200 kW to 500 kW of IT load, ships in 8 to 16 weeks, and needs only a foundation, power and network connection on site.

Last reviewed: 2026-11-07

Containers reduce site construction and can be shipped as a tested unit. The project must plan transport, foundation, power and network connections.

Cooling and fire strategy are designed for the container layout, not a conventional room.

Best for

  • Remote or temporary capacity
  • Fast deployment projects
  • Sites with limited construction resources

Key specifications

Container vs prefabricated

FormatMobilityTypical use
ContainerHighRemote/temporary
Prefabricated roomLowPermanent expansion

How to choose

01

Check transport

Confirm road, crane and foundation requirements.

02

Define services

Plan power, network, water and drainage.

03

Confirm cooling

Select cooling for the container heat load.

What a container data center is

A container data center is a data hall built inside an ISO container or a similar steel module. It includes racks, cooling, power distribution, UPS, fire suppression and monitoring. The module is factory-built, tested and shipped as a unit.

It is used for rapid deployment, temporary capacity, remote sites, military and disaster recovery. The ISO footprint simplifies transport by truck or ship and reduces on-site construction.

Size, rack count and layout

A 20 ft container typically holds 5 to 10 racks; a 40 ft container holds 10 to 20 racks. Racks are usually 600 mm or 800 mm wide and 1,200 mm deep, with a 1,200 mm aisle. The container includes a service aisle, a cooling area and a power room.

Confirm the internal dimensions, the door opening and the transport route. A 40 ft container needs a clear route, a crane or a heavy forklift, and a foundation designed for the weight.

Power, cooling and efficiency

A container module typically includes an integrated UPS, switchgear, busway and row or perimeter cooling. A 40 ft module can support 200 kW to 500 kW of IT load, depending on the cooling and power configuration.

Containment and a sealed envelope allow a higher supply temperature and a PUE of about 1.2 to 1.5. Free cooling is possible in suitable climates. For critical sites, use N+1 or 2N power and cooling.

Delivery and commissioning

Typical lead time is 8 to 16 weeks after drawing approval, depending on the module and the power/cooling configuration. Site work includes the foundation, module placement, power and network connection, cooling commissioning and integrated testing.

Container data center reference

Item20 ft40 ft
Racks5–1010–20
IT load100–250 kW200–500 kW
CoolingRow / perimeterRow / perimeter
UPSIntegratedIntegrated
PUE1.2–1.51.2–1.5
Lead time8–16 weeks8–16 weeks
TransportTruck / shipTruck / ship
Site work3–8 weeks4–10 weeks

Container vs prefabricated hall

ItemContainerPrefabricated hall
MobilityHighLow
Racks5–2010–100+
TransportISO standardCustom modules
ExpansionAdd containersAdd modules
Best forRemote / temporaryPermanent campus

Container options

OptionChoicesUse
Size20 ft / 40 ftCapacity
CoolingRow / perimeter / freeClimate
UPSN+1 / 2NCriticality
FireClean agentLocal code
MonitoringBMS / cloudO&M
TransportTruck / seaDistance

Frequently asked questions

Can a container be relocated?

Yes, but transport, foundation and service connections must be planned again.

How many racks fit?

It depends on the container size and cooling; the layout is confirmed at design.

Is it a modular data center?

A container is one modular format; modular data centers can also be room-based.

How many racks fit in a container data center?

A 20 ft container typically holds 5 to 10 racks; a 40 ft container holds 10 to 20 racks. The final count depends on the rack width, aisle width and power/cooling layout.

How much IT load can a 40 ft container support?

A 40 ft module typically supports 200 kW to 500 kW of IT load, depending on the cooling and power configuration. Confirm the heat load and the redundancy before selecting the module.

What is the lead time for a container data center?

Typical lead time is 8 to 16 weeks after drawing approval, plus 3 to 10 weeks of site work for the foundation, connections and commissioning.

Can a container data center be relocated?

Yes. The ISO footprint allows transport by truck or ship. Confirm the lifting points, the foundation design and the reconnection requirements before relocation.

What PUE does a container data center achieve?

Typical PUE is 1.2 to 1.5, depending on the climate, cooling mode and IT load. Free cooling and containment improve efficiency.